Problem We Helped Solve


Like most construction sites, only 80A of temporary building supply was available from the street, far below the >600A needed to operate all of the on-site equipment. Under traditional methods, the site would have required at least two 220kVA generators, resulting in high fuel consumption, emissions, noise and increased operating costs.

  • Deployed 1 x Powershift CP300 unit, trickle charging from just 32A of the TBS and powering the crane, concrete pump and hoists. This allowed the remaining TBS to cover general site building power.
  • The battery delivers high output instantly during demand spikes from the equipment and recharges efficiently during low-load periods, delivering power with maximum efficiency.
  • This solution eliminated the need for diesel generators altogether.

CP300 units are highly compact, plug-and-play battery systems specially designed to power high peak electric machinery such as cranes, hoists, booms, welders and more.

Although the calculated maximum demand exceeded 600A, real-world load diversity means the Powershift battery can efficiently manage peaks without compromising performance. The battery remains continuously trickle-charged from a 32A supply, discharging only when required and maintaining above 90% state-of-charge throughout the whole project.